Checking method of UV illumination intensity
4-44
Reference value of the measurement
The lamp illumination intensity before shipping and the theoretical value when the cumulative irradiation
time exceeds 1000 hours are indicated on the label located inside of the machine.
When the cumulative irradiation time exceeds 1000 hours, the illumination intensity will decrease by
30%.
After 1000 hours have passed, the illumination intensity will not decrease rapidly.
Even if the cumulative irradiation time does not exceed 1000 hours, when the illumination intensity
decreases rapidly, the UV lamp unit may be broken. Contact a nearby sales agency or our business
office.
Even if the illumination intensity decreases, it is possible that the ink will harden sufficiently by
changing the setting of the amount of UV light. Please refer to "Changing the UV illumination intensity"
( P.3-19 ).